A Comparison of Internal Target Volume Definition by Limited Four-dimensional Computed Tomography, the Addition of Patient-specific Margins, or the Addition of Generic Margins when Planning Radical Radiotherapy for Lymph Node-positive Non-small Cell Lung Cancer

  • S. Hughes

      Affiliations

    • Division of Imaging Sciences, King's College London, London, UK
    • Department of Radiotherapy, Guy's & St Thomas' Hospitals NHS Trust, London, UK
    • Corresponding Author InformationAuthor for correspondence: S. Hughes, Oncology Department, University College London Hospital, First Floor East, 250 Euston Road, London NW1 2PG, UK. Tel: +44-8451-555-000.
  • ,
  • J. McClelland

      Affiliations

    • Centre for Medical Image Computing, University College London, London, UK
  • ,
  • A. Chandler

      Affiliations

    • Division of Imaging Sciences, King's College London, London, UK
  • ,
  • M. Adams

      Affiliations

    • Department of Radiotherapy, Guy's & St Thomas' Hospitals NHS Trust, London, UK
  • ,
  • J. Boutland

      Affiliations

    • Department of Radiotherapy, Guy's & St Thomas' Hospitals NHS Trust, London, UK
  • ,
  • D. Withers

      Affiliations

    • Medical Physics Department, Guy's & St Thomas’ Hospitals NHS Trust, London, UK
  • ,
  • S. Ahmad

      Affiliations

    • Department of Radiotherapy, Guy's & St Thomas' Hospitals NHS Trust, London, UK
  • ,
  • J. Blackall

      Affiliations

    • Centre for Medical Image Computing, University College London, London, UK
  • ,
  • S. Tarte

      Affiliations

    • Centre for Medical Image Computing, University College London, London, UK
  • ,
  • D. Hawkes

      Affiliations

    • Centre for Medical Image Computing, University College London, London, UK
  • ,
  • D. Landau

      Affiliations

    • Division of Imaging Sciences, King's College London, London, UK
    • Department of Radiotherapy, Guy's & St Thomas' Hospitals NHS Trust, London, UK

Received 28 February 2007; received in revised form 20 November 2007; accepted 3 December 2007.

Abstract 

Aims

Radical radiotherapy for stage II/III non-small cell lung cancer (NSCLC) includes the primary tumour and positive mediastinal lymph nodes in the clinical target volume (CTV). These move independently of each other in magnitude and direction during respiration. To prevent a geographical miss, a generic margin is usually added to the CTV to create an internal target volume (ITV). Previous studies have investigated the use of additional breath-hold computed tomography to generate patient-specific ITVs for primary tumours alone. We used a similar technique to investigate the generation of patient-specific and generic ITVs for CTVs that include mediastinal lymph nodes.

Materials and methods

Thirteen patients with node-positive NSCLC had two limited end-tidal breath-hold computed tomography scans in addition to their planning computed tomography. The CTV was segmented in each scan and a rigid registration was carried out on the vertebral columns to align them. Different methods for generating an ITV were then analysed.

Results

Generic margins provided >95% mean coverage of the reference ITV. However, with the exception of 1cm expansion margins, there were cases of inadequate coverage (<95%) for each ITV. With increasing ITV margins there was a small increase in reference ITV coverage, but at the expense of a large increase in the volume of normal tissue within the ITV.

Discussion

For stage II/III NSCLC, ITV generation by the addition of a generic margin is not optimal. It can result in both geographical miss and excessive irradiation of normal tissue in the same treatment plan. A simple method for producing a patient-specific ITV is to co-register end-tidal breath-hold computed tomography scans to the planning scan.

Conclusions

Further work is required to determine whether end-tidal breath-hold scans are representative of the anatomy at the limits of tidal respiration. Planning strategies are also needed to account for breathing cycle variation during a course of radiotherapy.

Key words: ITV, NSCLC, respiratory motion

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0936-6555(07)00927-2

doi:10.1016/j.clon.2007.12.004

Clinical Oncology
Volume 20, Issue 4 , Pages 293-300, May 2008